Equator 375 Wartungshandbuch Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
1.2. Trouble-Shooting in the Electric Circuit.
Before systematic trouble-shooting is commenced, check to
ensure that:
- The fuses are intact.
- The correct voltage has been used (vo!trneter).
- The electrical equipment used is suitable for the cam-
pressOr.
- The wiring has been correcUy installed (compare with
wiring diagram as found in the spare parts list).
- There is no leakage between the live parts and the frame
(see Section 1.3).
Example of wiring diagram: Diagram BKF, BMC, BSKF.